industrial qualification process for optical fibers distributed strain and temperature sensing in nuclear waste repositories
Clicks: 177
ID: 213203
2012
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Popular Article
30.0
/100
177 views
30 readers
AI Quality Assessment
Not analyzed
Readership in this journal
PopularRanked #90 of 205 articles by views in BMC infectious diseases
Most read
Least read
Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 205 in total.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Temperature and strain monitoring will be implemented in the envisioned French geological repository for high- and intermediate-level long-lived nuclear wastes. Raman and Brillouin scatterings in optical fibers are efficient industrial methods to provide distributed temperature and strain measurements. Gamma radiation and hydrogen release from nuclear wastes can however affect the measurements. An industrial qualification process is successfully proposed and implemented. Induced measurement uncertainties and their physical origins are quantified. The optical fiber composition influence is assessed. Based on radiation-hard fibers and carbon-primary coatings, we showed that the proposed system can provide accurate temperature and strain measurements up to 0.5 MGy and 100% hydrogen concentration in the atmosphere, over 200 m distance range. The selected system was successfully implemented in the Andra underground laboratory, in one-to-one scale mockup of future cells, into concrete liners. We demonstrated the efficiency of simultaneous Raman and Brillouin scattering measurements to provide both strain and temperature distributed measurements. We showed that 1.3 μm working wavelength is in favor of hazardous environment monitoring.
| Reference Key |
delepine-lesoille2012journalindustrial
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | ;S. Delepine-Lesoille;X. Phéron;J. Bertrand;G. Pilorget;G. Hermand;R. Farhoud;Y. Ouerdane;A. Boukenter;S. Girard;L. Lablonde;D. Sporea;V. Lanticq |
| Journal | BMC infectious diseases |
| Year | 2012 |
| DOI |
10.1155/2012/369375
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org