comparison of the performance of disk diffusion, agar screening and e-test methods with real-time pcr for the detection of methicillin resistant coagulase negative staphylococcus strains isolated from clinical samples of shahrekord university hospitals, 2008

Clicks: 231
ID: 213197
2012
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Steady

Ranked #83 of 129 articles by views in The Journal of Chemical Physics

Most read Least read

Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 129 in total.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Background: Coagulase Negative staphylococci (CoNS) are nosocomial pathogens. The main objective of the study was to compare the performance of disk diffusion, E-test and agar screening methods with Real-time PCR technique for detection of methicillin resistance in coagulase negative staphylococci (MRCoNS), using Taqman® Real-time PCR for mecA as the “gold standard” comparison assay. Methods: 88 coagulase negative Staphylococcus isolates were identified out of 284 Staphylococcus isolates collected from Hajar and Kashani hospitals-shahrekod, Iran. Methicillin resistance strains were identified by several methods: Disk diffusion, Agar screening, E-test and Real-time PCR. The results of the tested methods were compared with those of the Real-time PCR by Chi square or Fisher’s exact tests. Results: Of the 88 coagulase negative Staphylococcus isolates tested, 46 isolates (52.3%) were mecA-positive and 42 isolates (47.7%) were mecA-negative. The results of all the tested methods had a statistically significant agreement with those of Real-time PCR. The E-test was 100% sensitive and specific for mecA presence. The sensitivity and specificity of oxacillin agar screen (6.0 μg/ml) method were 96% and 98%, respectively and the sensitivity and specificity of oxacillin Disk diffusion method were 91% and 90%, respectively. Conclusion: In the present study, E-test is proposed as the best phenotypic method. In case economic issue matters, the oxacillin agar screening method (6.0 μg/ml), which is suitable for the detection of MRCoNS due to its accuracy and low cost, is recommended.
Reference Key
shariati2012iraniancomparison Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors ;Laleh Shariati;Majid Validi;Mana Shojapour;Ali Mohammad Hasheminia;Mohammad Amin Tabatabaiefar;Ali Karimi;Mohammad Reza Nafisi
Journal The Journal of Chemical Physics
Year 2012
DOI
DOI not found
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.