critical system cascading collapse assessment for determining the sensitive transmission lines and severity of total loading conditions

Clicks: 127
ID: 212565
2013
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Steady

Ranked #515 of 1,093 articles by views in journal of power sources

Most read Least read

Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 1,093 in total.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
This paper presents a computationally accurate technique used to determine the estimated average probability of a system cascading collapse considering the effect of hidden failure on a protection system. This includes an accurate calculation of the probability of hidden failure as it will give significant effect on the results of the estimated average probability of system cascading collapse. The estimated average probability of a system cascading collapse is then used to determine the severe loading condition contributing to a higher risk of a system cascading collapse. This information is important because it will assist the utility to determine the maximum level of increase in the system loading condition before the occurrence of critical power system cascading collapse. Furthermore, the initial tripping of sensitive transmission line contributing to a critical system cascading collapse can also be determined by using the proposed method. Based on the results obtained from this study, it was found that selecting the accurate probability of hidden failure is very important as it will affect the estimated average probability of a system cascading collapse. Comparative study has been done with other techniques to verify the effectiveness of the proposed method used in the determination of sensitive transmission lines.
Reference Key
salim2013mathematicalcritical Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors ;Nur Ashida Salim;Muhammad Murtadha Othman;Ismail Musirin;Mohd Salleh Serwan
Journal journal of power sources
Year 2013
DOI
10.1155/2013/965628
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.