low in vitro third-body wear on total hip prostheses induced by calcium sulphate used for local antibiotic therapy
Clicks: 145
ID: 212508
2014
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
30.0
/100
145 views
24 readers
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #28 of 28 articles by views in vestnik volgogradskogo gosudarstvennogo universiteta seriâ 11 estestvennye nauki
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
In case of implant associated infection, implant preservation is associated with high failure rates. Therefore, a removal or exchange of the implant is most often mandatory for treatment success. Alternatively, under certain conditions, local antibiotic delivery can be applied – preserving the implant, using for example calcium sulphate as a resorbable carrier. In this work, third-body wear on total hip prostheses caused by calcium sulphate particles was tested in a hip simulator. Inlays made of ultra-high-molecular-weight polyethylene (UHMWPE) and cross-linked polyethylene (XLPE) against 28 mm CoCrMo heads and 36 mm alumina pairings were tested in triplicate, both with and without calcium sulphate particles in the test liquid.
Neither the alumina articulations nor the CoCrMo heads were affected by the calcium sulphate particles since calcium sulphate is a relatively soft material. The polyethylene inlays showed 39-89 % higher wear during exposure compared to references, but wear returned to normal when no more particles were added. Thus, calcium sulphate might be used as antibiotic carrier even in the presence of total hip prostheses without fearing excessive third-body wear.
| Reference Key |
heuberger2014europeanlow
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | ;R Heuberger;P Wahl;J Krieg;E Gautier |
| Journal | vestnik volgogradskogo gosudarstvennogo universiteta seriâ 11 estestvennye nauki |
| Year | 2014 |
| DOI |
DOI not found
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.