comparison of fluid filtration and bacterial leakage techniques for evaluation of microleakage in endodontics
Clicks: 192
ID: 212354
2015
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
30.0
/100
192 views
25 readers
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #45 of 59 articles by views in Mycoses
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Background: Apical leakage assessment is a way to compare the efficiency of a filling material to seal the apical region of the tooth. Many microleakage testing techniques have been introduced through the years, but there has been no agreement as to which technique gives the most accurate results. The aim of this study was to compare the accuracy of fluid filtration and bacterial leakage techniques in the assessment of the apical sealing ability of mineral trioxide aggregate (MTA) and calcium enriched mixture (CEM).
Materials and Methods: A sample of 34 extracted single-rooted human teeth were selected and prepared. The samples were divided in to 2 experimental groups. The apical 3 mm of each root was resected at 90° to its long axis and root end preparation was done with ultrasonic tips to a depth of 3 mm and filled with MTA and CEM, respectively. Assessment of apical sealing ability was done with fluid filtration technique and bacterial leakage technique along 90 days with Enterococcus faecalis bacteria. Mann-Whitney U-test and Chi-square test were used to analyze the data using SPSS (SPSS Inc., Chicago, IL, USA). P less than 0.05 was considered as significant.
Results: There was no significant difference in apical sealing ability between MTA and CEM in bacterial leakage and fluid filtration techniques. Samples which had bacterial leakage showed higher leakage values by fluid filtration technique.
Conclusion: Both techniques showed same results and there was no significant difference between fluid filtration and bacterial leakage techniques in assessment of apical microleakage.
| Reference Key |
moradi2015dentalcomparison
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | ;Saeed Moradi;Mahdi Lomee;Maryam Gharechahi |
| Journal | Mycoses |
| Year | 2015 |
| DOI |
DOI not found
|
| URL | |
| Keywords | Keywords not found |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.