impact of asynchronous renewable generation infeed on grid frequency: analysis based on synchrophasor measurements
Clicks: 158
ID: 211261
2018
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
30.0
/100
158 views
23 readers
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #726 of 935 articles by views in journal of physics: conference series
Most read
Least read
Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 935 in total.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
The increasing power in-feed of Non-Synchronous Renewable Energy Sources (NS-RES) in the grid has raised concerns about the frequency stability. The volatile RES power output and absence of inertia in many types of NS-RES affect the balance between power consumption and production. Therefore, the dynamics of the power grid frequency become more complex. Extreme grid frequency deviations and fast variations can lead to partitioning and load shedding in the case of under-frequency. In the case of over-frequency, it can lead to overloading, voltage collapse and blackouts. The Rate of Change of Frequency (RoCoF) reflects an aspect of the stability status of the grid and therefore its analysis with regard to Non-Synchronous Instant Penetration (NSIP) is of great importance. In this work, two months of high-resolution frequency synchrophasor measurements during 18 January 2018–18 March 2018 recorded in Austria were analyzed to investigate the impact of NS-RES on the frequency. The correlation of RoCoF with the NSIP in Austria and Germany and with the frequency deviation were examined. It was observed that with a maximum NSIP share up to 74 % of the total power generation in these two countries, there was no critical increase of RoCoF or abnormal frequency deviation in the power grid.
| Reference Key |
xypolytou2018sustainabilityimpact
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | ;Evangelia Xypolytou;Wolfgang Gawlik;Tanja Zseby;Joachim Fabini |
| Journal | journal of physics: conference series |
| Year | 2018 |
| DOI |
10.3390/su10051605
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.