Comparison of Mannequin Training Satisfaction with a Conventional Box Trainer and a Low-Fidelity Fetoscopic Surgical Simulator for Selective Fetoscopic Laser Photocoagulation.

Clicks: 341
ID: 21103
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Star

Ranked #4 of 4 articles by views in fetal diagnosis and therapy

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
A low-fidelity fetoscopic surgical simulator (FSS) for training of selective fetoscopic laser photocoagulation (SFLP) was developed.To evaluate and compare training satisfaction with an FSS and with a conventional box trainer (BT).The BT consisted of a cleaned human placenta attached to the inside of a plastic storage box with a watertight lock cover and an ultrasound-transparent rubber skin. The FSS consisted of the replica of a monochorionic twin placenta attached to the inside of a spherically shaped, ultrasound-transparent phantom. Tap water was used as an ultrasound conduction agent. Evaluation of the mannequin trainings was conducted on 8 junior maternal-fetal medicine (MFM) attending physicians and 22 MFM fellows. Training satisfaction was scored from 0 to 10 on 8 different domains.The mean satisfaction score (±SD) with the FSS was higher than with the BT in all domains (p < 0.05). The fellows' training satisfaction with the BT was greater than that of the attending physicians in 4 domains: tactile feedback, demonstration of chorionic vessels, feedback on performance, and overall value as learning aid (p < 0.05).As evaluated by a small group of trainees, our FSS is superior to the BT in mannequin training of SFLP. However, the BT may be more useful for trainees with limited clinical experience.
Reference Key
wataganara2019comparisonfetal Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors Wataganara, Tuangsit;Viboonchart, Sommai;Chumthup, Wangcha;Chuenwattana, Prakong;Pooliam, Julaporn;Nawapun, Katika;Phithakwatchara, Nisarat;
Journal fetal diagnosis and therapy
Year 2019
DOI
10.1159/000502180
URL
Keywords Keywords not found

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.