evaluation of indoor air quality screening strategies: a step-wise approach for iaq screening

Clicks: 276
ID: 210868
2016
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Steady

Ranked #359 of 642 articles by views in archives of biochemistry and biophysics

Most read Least read

Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 642 in total.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Conducting a full indoor air quality (IAQ) assessment in air-conditioned offices requires large-scale material and manpower resources. However, an IAQ index can be adopted as a handy screening tool to identify any premises (with poor IAQ) that need more comprehensive IAQ assessments to prioritize IAQ improvements. This study proposes a step-wise IAQ screening protocol to facilitate its cost-effective management among building owners and managers. The effectiveness of three IAQ indices, namely θ1 (with one parameter: CO2), θ2 (with two parameters: CO2 and respirable suspended particulates, RSP) and θ3 (with three parameters: CO2, RSP, and total volatile organic compounds, TVOC) are evaluated. Compared in a pairwise manner with respect to the minimum satisfaction levels as stated in the IAQ Certification Scheme by the Hong Kong Environmental Protection Department, the results show that a screening test with more surrogate IAQ parameters is good at identifying both lower and higher risk groups for unsatisfactory IAQ, and thus offers higher resolution. Through the sensitivity and specificity for identifying IAQ problems, the effectiveness of alternative IAQ screening methods with different monitoring parameters is also reported.
Reference Key
wong2016internationalevaluation Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors ;Ling-tim Wong;Kwok-wai Mui;Tsz-wun Tsang
Journal archives of biochemistry and biophysics
Year 2016
DOI
10.3390/ijerph13121240
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.