clinical and radiological outcome of titanium implants in clinical practice: a 5 year, prospective, multicenter case series

Clicks: 304
ID: 210309
2014
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Popular

Ranked #20 of 31 articles by views in journal of cellular biochemistry

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
The objective of this prospective clinical case series was to confirm the 5-year clinical and radiographic performance of titanium implants occlusally loaded after 12 weeks. Periapical X-rays for quantitative bone level assessment were taken immediately post-surgery, after loading, 6 and 12 months, and 5 years after loading. Pocket depth (PD) and clinical attachment level (CAL) were measured. One-hundred and fourteen implants were inserted in 71 consecutive patients; 111 (97%) implants/69 (97%) patients were followed for 5 years. One implant was lost before loading (acute infection of unknown origin). Another patient developed peri-implantitis in the healing phase, and underwent successful surgical revision. Mesial median bone level at 6 and 12 months, and 5 years was 1.2 (SD ± 0.7), 1.3 (SD ± 0.7) and 1.1 (SD ± 0.6) mm; distal values were: 1.1 (SD ± 0.7), 1.4 (SD ± 0.7) and 1.2 (SD ± 0.6) mm; below implant shoulder. Stable CAL (1.2–1.6 mm) and PD (2.0–3.0 mm) were found. After 5 years no implant was lost. Three crowns and one abutment screw were defective and replaced. Implant survival (1 failure/114) as well as minimal peri-implant bone loss confirmed the favorable outcome of the used implant line. Five years post-loading, crestal bone stabilized slightly below the machined/rough border.
Reference Key
jaquiry2014dentistryclinical Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors
Journal journal of cellular biochemistry
Year 2014
DOI
10.3390/dj2040106
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.