A novel enzyme-free electrochemical biosensor for rapid detection of Pseudomonas aeruginosa based on high catalytic Cu-ZrMOF and conductive Super P.
Clicks: 470
ID: 2086
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
70.3
/100
470 views
329 readers
Trending
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #6 of 85 articles by views in Biosensors & bioelectronics
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Pseudomonas aeruginosa (P. aeruginosa) is one of the most intractable multidrug-resistant bacteria of nosocomial infections. The conventional detection methods for P. aeruginosa are time-consuming or low detection sensitivity. Here, a novel enzyme-free electrochemical biosensor was constructed to detect P. aeruginosa rapidly and sensitively. Firstly, the ZrMOF with large surface area was synthesized, which offers excellent adsorption. Further, it was connected with a specific amount of Cu to synthesize Cu-ZrMOF with high catalytic activity. Then the Cu-ZrMOF@Aptamer@DNA nanocomposite was composed and served as the signal probe to catalyse the decomposition of HO. Moreover, high conductive Super P was introduced to increase the electron transfer for satisfactory detection sensitivity. The proposed biosensor was constructed and used to quantify P. aeruginosa with a wide linearity range of 10-10 CFU mL and a low limit of detection of 2 CFU mL (S/N = 3). Compared with conventional methods, the new method of present biosensor is more sensitive, and less time-consuming (only within 120 min). The analytical performance evaluation indicated that the biosensor exhibits good reproducibility and specificity. Finally, the biosensor was successfully applied to quantify P. aeruginosa in spiked urine samples. These results show that the proposed electrochemical biosensor might be a potential laboratory tool for detecting P. aeruginosa in the clinic.
| Reference Key |
zhang2019abiosensors
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Zhang, Xin;Xie, Guoming;Gou, Dan;Luo, Peng;Yao, Yuan;Chen, Hui; |
| Journal | Biosensors & bioelectronics |
| Year | 2019 |
| DOI |
S0956-5663(19)30565-2
|
| URL | |
| Keywords | Keywords not found |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.