OFBG-Based Smart Double-Skin Tubular Confined-Concrete Column with Basalt FRP-Steel Composite.
Clicks: 278
ID: 20858
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
80.6
/100
278 views
228 readers
Trending
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #714 of 1,694 articles by views in sensors
Most read
Least read
Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 1,694 in total.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Fiber-reinforced polymer (FRP) composites have been widely employed to design advanced structural columns such as the hybrid FRP-concrete-steel double-skin tubular column (hybrid DSTC) with potential benefits. To date, the safety and self-monitoring of the hybrid DSTCs are still a challenge to overcome due to the complex damage scenarios. This paper investigates the self-sensing performance of a newly developed smart double-skin tubular confined concrete column (smart BFST-DSTC) made of basalt FRP-steel composite with built-in optical fiber Bragg grating sensors (OFBGs). The design of the smart BFST-DSTC and sensing principle are firstly addressed, followed by an experimental investigation on the basic mechanical properties and strain-based sensing performance of ten scaled specimens under axial compression. The outcomes reveal the enhancement of the proposed column in terms of load-carrying capacity, confinement ratio, and axial stress-axial strain behavior, as well as failure and damage modes when compared with the hybrid DSTC. The self-sensing investigation demonstrates that the measurement range satisfies the requirement to monitor and evaluate the hoop strains of the FRP jackets and the health state of the inner tube. The smart BFST-DSTC can replace the hybrid DSTC with the ability to provide early failure warning and life cycle health monitoring.
| Reference Key |
sasy-chan2019ofbgbasedsensors
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Sasy Chan, Yung William;Zhou, Zhi;Liu, Wanqiu;Ou, Jinping; |
| Journal | sensors |
| Year | 2019 |
| DOI |
E3572
|
| URL | |
| Keywords | Keywords not found |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.