microcirculation under an elastic bandage during rest and exercise - preliminary experience with the laser-doppler spectrophotometry system o2c
Clicks: 263
ID: 208104
2013
Article Quality & Performance Metrics
Overall Quality
Improving Quality
0.0
/100
Combines engagement data with AI-assessed academic quality
Reader Engagement
Steady Performance
79.4
/100
258 views
210 readers
Trending
AI Quality Assessment
Not analyzed
Abstract
There is an abundace of studies on the influence of rest and exercise as well as external compression on cutaneous, subcutaneous and muscle tissue blood flow using different measurement techniques. As a novel approach, we simultaneously examined the influence of a custom- made elastic thigh bandage on cutaneous and subcutaneous venous blood oxygenation (SO2), postcapillary venous filling pressures (rHb) and blood flow (flow) using the non-invasive laser- Doppler spectrophotometry system "Oxygen-to-see(O2C)". Parameters were obtained in 20 healthy volunteers in 2 mm and 8 mm tissue depth during rest, 5 and 10 minutes of moderate bicycle exercise following a 10-minute recovery period. Without the bandage, results matched the known physiological changes indicating higher blood backflow from superficial and deep veins. Underneath the elastic bandage, we observed lower post-capillary filling pressures during exercise. However, after the bandage was removed in the post-exercise period, all obtained parameters of microcirculation remained increased, indicating a higher amount of local venous blood volume in this area. Our observations might be the result of external compression, thermoregulatory and exercise-dependent vascular mechanisms. With the O2C device, a promising new non- invasive technique of measuring local microcirculation in soft tissue exists. This study gives new insights in the field of non-invasive diagnostics with special regard to the influence of elastic bandages on local microcirculation
Abstract Quality Issue:
This abstract appears to be incomplete or contains metadata (213 words).
Try re-searching for a better abstract.
| Reference Key |
sommer2013journalmicrocirculation
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | ;Hans-Martin Sommer;Gereon Berschin;Björn Sommer |
| Journal | journal of the turkish chemical society section a: chemistry |
| Year | 2013 |
| DOI |
DOI not found
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.