on the “zero of potential of the electric field produced by the heart beat”. a machine capable of estimating this underlying persistent error in electrocardiography

Klik: 313
ID: 207538
2016
Metrik Kualitas & Kinerja Artikel
Kualitas Keseluruhan
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
Penilaian Kualitas AI
Belum dianalisis
Readership in this journal
Steady

Ranked #5 of 16 articles by views in neuroethics

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstrak
Modern electrocardiography (ECG) uses a constructed reference potential for the majority of leads. This reference potential, named after its inventor as the Wilson central terminal, is assumed to have negligible value and to be stationary during the cardiac cycle. However, the problem of its variability during the cardiac cycle has been known almost since the inception of 12-lead electrocardiography. Due to the cumbersomeness of the measurement system required to fully appreciate these variations, this topic has received scant research attention during the last 60 years. Taking advantage of modern electronic amplifiers’ capability to detect small voltages, drawing only femtoamperes from physiological equivalent signal sources and of the right-leg connection availability, we developed a complete electrocardiography device that, aside from the eight independent signals of the standard 12-lead ECG, allows direct recording of the Wilson central terminal components. In this paper, we present details of the circuit together with its initial clinical evaluation. For this trial, we recorded data from 44 volunteer patients at Campbelltown Hospital (Campbelltown, Australia) and we found that the Wilson central terminal amplitude, as foreseen by Frank and others in the 1950s, is not negligible, its amplitude in relation to the lead II is, on average, 51.2%, and thus it may be clinically relevant.
Kunci Referensi
gargiulo2016machineson Gunakan kunci ini untuk mengutip otomatis dalam naskah saat menggunakan SciMatic Manuscript Manager atau Thesis Manager
Penulis
Jurnal neuroethics
Tahun 2016
DOI
10.3390/machines4040018
URL
Kata Kunci

Sitasi

Tidak ada sitasi yang ditemukan. Untuk menambahkan sitasi, hubungi admin di info@scimatic.org

Belum ada komentar. Jadilah yang pertama berkomentar pada artikel ini.