significance of the spatial reconstruction based on mathematical modeling in the surgical treatment of giant intracranial aneurysms

Clicks: 209
ID: 206973
2006
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Steady

Ranked #121 of 134 articles by views in applied nursing research : anr

Most read Least read

Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 134 in total.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Background. The use of computer models for the 3- dimensional reconstruction could be a reliable method to overcome technical imperfections of diagnostic procedures for the microsurgical operation of giant intracranial aneurysms. Case report. We presented a case of successfully operated 52-year-old woman with giant intracranial aneurysm, in which the computer 3-dimensional reconstruction of blood vessels and the aneurysmal neck had been decisive for making the diagnosis. The model for 3- dimensional reconstruction of blood vessels was based on the two 2-dimensional projections of the conventional angiography. Standard neuroradiologic diagnostic procedures showed a giant aneurysm on the left middle cerebral artery, but the conventional subtraction and CT angiography did not reveal enough information. By the use of a personal computer, we performed a 3-dimensional spatial reconstruction of the left carotid artery to visualize the neck of aneurysm and its supplying blood vessels. Conclusion. The 3-dimensional spatial reconstruction of the cerebral vessels of a giant aneurysm based on the conventional angiography could be useful for planning the surgical procedure.
Reference Key
m.2006vojnosanitetskisignificance Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors ;Nikolić Igor M.;Nagulić Mirjana;Antunović Vaso
Journal applied nursing research : anr
Year 2006
DOI
10.2298/VSP0601065N
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.