analysis and control of induction generator supplying stand-alone ac loads employing a matrix converter
Clicks: 171
ID: 206475
2017
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
30.0
/100
171 views
28 readers
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #374 of 430 articles by views in International journal of molecular sciences
Most read
Least read
Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 430 in total.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
This paper proposes a Capacitor Excited Induction Generator (CEIG)-Matrix Converter (MC) system for feeding stand-alone AC loads. The variable output voltage magnitude and frequency from CEIG is converted into a constant voltage magnitude and frequency at the load terminals by controlling MC using Space Vector Modulation (SVM) technique. This single-stage MC is turned up as a good alternative for the proposed system against commonly used AC/DC/AC two stage power converters. The configuration and implementation of the closed-loop control scheme employing dSPACE 1103 real time controller have been fully described in the paper. The proposed closed-loop controller regulates the AC load voltage irrespective of changes in the prime mover speed and load. A method for predetermining the steady-state performance of the proposed system has been developed and described with relevant analytical expressions. The effectiveness of the proposed system is exemplified through simulation results for various operating conditions. The proposed control technique is further validated using an experimental setup developed in the laboratory.
| Reference Key |
mahajan2017engineeringanalysis
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | ;Sumedha Mahajan;SenthilKumar Subramaniam;Kumaresan Natarajan;Ammasai Gounden Nanjappa Gounder;Devendra Varma Borru |
| Journal | International journal of molecular sciences |
| Year | 2017 |
| DOI |
10.1016/j.jestch.2017.02.006
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.