inductive-based wireless power recharging system for an innovative endoscopic capsule

Clicks: 104
ID: 206104
2015
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Steady

Ranked #472 of 526 articles by views in acs combinatorial science

Most read Least read

Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 526 in total.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Wireless capsule endoscopic devices are adopted for painless diagnosis of cancer and other diseases affecting the gastrointestinal tract as an alternative to traditional endoscopy. Although much work has been done to improve capsule performance in terms of active navigation, a major drawback is the limited available energy on board the capsule, usually provided by a battery. Another key shortcoming of active capsules is their limitation in terms of active functionalities and related costs. An inductive-based wireless recharging system for the development of an innovative capsule for colonoscopy is proposed in this paper; the aim is to provide fast off-line battery recovery for improving capsule lifecycle and thus reducing the cost of a single endoscopic procedure. The wireless recharging system has been properly designed to fit the dimensions of a capsule for colonoscopy but it can be applied to any biomedical devices to increase the number of times it can be used after proper sterilization. The current system is able to provide about 1 W power and is able to recharge the battery capsule in 20 min which is a reasonable time considering capsule operation time (10–15 min).
Reference Key
tortora2015energiesinductive-based Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors ;Giuseppe Tortora;Francesca Mulana;Gastone Ciuti;Paolo Dario;Arianna Menciassi