An enhanced flow-thermo-structural modeling and validation for the integrated analysis of a film cooling nozzle guide vane
Clicks: 111
ID: 20600
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Star Article
71.5
/100
111 views
91 readers
Trending
AI Quality Assessment
Not analyzed
Readership in this journal
StarRanked #210 of 220 articles by views in energies
Most read
Least read
Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 220 in total.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
The target of this paper is to develop an enhanced flow-thermo-structural (FTS) model with high computational accuracy, to perform the integrated analysis of film cooling nozzle guide vane (NGV). An efficient turbulence model and weak spring approach are utilized in the enhanced FTS model. In respect of the power balance principle of aeroengine rotor shaft and temperature test of a typical combustor, the mean temperature inlet and five normalization temperature curves were confirmed, respectively. The temperature-sensitive paint (TSP) technology was used to verify the numerical simulation. From this study, we find that the predicted temperature caters for the TSP test well, between which the maximum error is less than 6%, and the maximum thermal stress is 758 MPa around the hole edges and the location of stress concentration keeps the consistency with that of the cracks. The maximum thermal stress increases by 10% with the increasing inlet temperature and reduces by about 16% with the shifting of flame peak from the outer to inner hub. The prediction provides general information on the initiation of cracks on a vane segment. The developed enhanced FTS model is validated to be workable and precise in the integrated analysis of film cooling NGV. The efforts of this study provide an integrated analysis approach of film cooling NGV and are promising to provide guidance for the integrated design of film cooling components besides NGV.
| Reference Key |
guan2019anenergies
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Guan, P. |
| Journal | energies |
| Year | 2019 |
| DOI |
10.3390/en12142775
|
| URL | |
| Keywords | Keywords not found |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.