Enhancement of PV/T-integrated single slope solar desalination still productivity using water film cooling and hybrid composite insulation.

Clicks: 300
ID: 20560
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Steady

Ranked #195 of 403 articles by views in Environmental science and pollution research international

Most read Least read

Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 403 in total.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
This context is about enhancing the freshwater production of a single slope solar desalination still (SSSDS) using water film cooling over the glass cover and using hybrid natural fibre composite (HNFC) insulation. In contrast to the conventional insulations, we proposed the HNFC insulation; this composite was made of natural fibre Pharsalus vulgaris (6 %) and nano-silica (1 %) with unsaturated polyester resin. In this study, conventional SSSDS and proposed SSSDS with enhanced evaporation and condensation have been designed. The same was built with native materials. A conventional and proposed type SSSDS was subjected to the same experimental condition. The experimental result showed that using water film cooling over glass cover and HNFC insulation at 0.5 cm depth caused a 35% increase in the amount of distilled water when compared with the conventional type SSSDS with polystyrene-Styrofoam (thermocol) insulation. Water film cooling over glass cover and HNFC insulation at 1 cm depth caused a 21% increase in the amount of distilled water when compared with the conventional type SSSDS with thermocol insulation. The conventional type solar desalination still with thermocol insulation at 0.5 and 1 cm depth yields are 1.665 and 1.171 l/m/day, respectively, and the proposed solar desalination still with water film cooling over glass cover and HNFC insulation at 0.5 and 1 cm depth yields are 2.253 and 1.420 l/m/day, respectively.
Reference Key
balachandran2019enhancementenvironmental Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors Balachandran, Gurukarthik Babu;David, Prince Winston;Vijayakumar, Aravind Bhaskar Panayilvedu;Kabeel, Abd Elnaby;Athikesavan, Muthu Manokar;Sathyamurthy, Ravishankar;
Journal Environmental science and pollution research international
Year 2019
DOI
10.1007/s11356-019-06131-9
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.