Structural design of a positioning spherical parallel manipulator to be utilized in brain biopsy.
Clicks: 320
ID: 20316
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Star Article
73.1
/100
320 views
234 readers
Trending
AI Quality Assessment
Not analyzed
Readership in this journal
StarRanked #2 of 3 articles by views in the international journal of medical robotics + computer assisted surgery : mrcas
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
During the last decades, there has been a great increase in the usage of robotic systems during surgeries in order to reach increased operational precision, reduced operation times, enhanced recovery periods, low infection risks, and limited scar formations for aesthetic reasons. In light of this, the current study focuses on the field of robotic surgery by introducing the kinematic structure of the precise robotic positioning manipulator for brain biopsy.Throughout the study, two degrees of freedom spherical parallel robot manipulator was proposed in order to position brain biopsy needle precisely during the brain biopsy operation on the target workspace.Direct and inverse kinematics of the manipulator were carried out parametrically by using quaternion algebra. The prototype of the manipulator was manufactured by rapid prototyping for hardware verification.Hardware verification of the manufactured prototype was completed distinctly by using motion capture cameras and manufactured mock-up setup that mimics tumour locations inside the brain. Successful verification results in terms of precision were achieved.
| Reference Key |
gezgin2019structuralthe
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Gezgin, Erkin;Özbek, Seda;Güzin, Didem;Ağbaş, Ozan Emre;Gezer, Emin Burak; |
| Journal | the international journal of medical robotics + computer assisted surgery : mrcas |
| Year | 2019 |
| DOI |
10.1002/rcs.2011
|
| URL | |
| Keywords | Keywords not found |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.