a broadband optical cavity spectrometer for measuring weak near-ultraviolet absorption spectra of gases

Clicks: 179
ID: 202797
2011
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Popular

Ranked #87 of 183 articles by views in bioorganic & medicinal chemistry

Most read Least read

Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 183 in total.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Accurate absorption spectra of gases in the near–ultraviolet (300 to 400 nm) are essential in atmospheric observations and laboratory studies. This paper describes a novel incoherent broadband cavity-enhanced absorption spectroscopy (IBBCEAS) instrument for measuring very weak absorption spectra from 335 to 375 nm. The instrument performance was validated against the <sup>3</sup>B<sub>1</sub>-X<sup>1</sup>A<sub>1</sub> transition of SO<sub>2</sub>. The measured absorption varied linearly with SO<sub>2</sub> column density and the resulting spectrum agrees well with published spectra. Using the instrument, we report new absorption cross-sections of O<sub>3</sub>, acetone, 2-butanone, and 2-pentanone in this spectral region, where literature data diverge considerably. In the absorption minimum between the Huggins and Chappuis bands, our absorption spectra fall at the lower range of reported ozone absorption cross-sections. The spectra of the ketones agree with prior spectra at moderate absorptions, but differ significantly at the limits of other instruments' sensitivity. The collision-induced absorption of the O<sub>4</sub> dimer at 360.5 nm was also measured and found to have a maximum cross-section of ca. 4.0&times;10<sup>&minus;46</sup> cm<sup>5</sup> molecule<sup>−2</sup>. We demonstrate the application of the instrument to quantifying low concentrations of the short-lived radical, BrO, in the presence of stronger absorptions from Br<sub>2</sub> and O<sub>3</sub>.
Reference Key
chen2011atmospherica Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors ;J. Chen;D. S. Venables
Journal bioorganic & medicinal chemistry
Year 2011
DOI
10.5194/amt-4-425-2011
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.