estimación del tamaño óptimo de una unidad de hemodiálisis con base en el potencial de su infraestructura
Clicks: 486
ID: 201964
2010
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
75.7
/100
486 views
343 readers
Trending
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #22 of 219 articles by views in journal of anatomy
Most read
Least read
Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 219 in total.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Objetivo. Obtener estimaciones para el tamaño óptimo de unidades de hemodiálisis considerando los factores en la producción de este servicio. Material y métodos. Se realizó un estudio en México en 2009. Se analizan algunos métodos para calcular el tamaño óptimo de una unidad de hemodiálisis bajo diferentes condiciones: mercado monopolístico, en competencia perfecta y maximización de producción. Resultados. Una unidad óptima con base en los supuestos de este ejercicio de estimación debería de contar con: 16 dializadores (15 activos, uno de reserva) y una purificadora de agua que pueda abastecerlos. Además son necesarios un médico nefrólogo y cinco enfermeras por cada dos turnos, con cuatro turnos por día. Conclusión. Comparando lo óptimo con lo observado en estudios recientes de México, se observan ineficiencias en la operación, particularmente por desaprovechar tanto el potencial del equipo de filtrado de agua como el equipo de salud.
Objective. To estimate the optimum size for hemodialysis units to maximize production given capital constraints. Materials and Methods. A national study in Mexico was conducted in 2009. Three possible methods for estimating a unit's optimum size were analyzed: hemodialysis services production under monopolistic market, under a perfect competitive market and production maximization given capital constraints. Results. The third method was considered best based on the assumptions made in this paper; an optimal size unit should have 16 dialyzers (15 active and one back up dialyzer) and a purifier system able to supply all. It also requires one nephrologist, five nurses per shift, considering four shifts per day. Conclusion. Empirical evidence shows serious inefficiencies in the operation of units throughout the country. Most units fail to maximize production due to not fully utilizing equipment and personnel, particularly their water purifier potential which happens to be the most expensive asset for these units.
Objective. To estimate the optimum size for hemodialysis units to maximize production given capital constraints. Materials and Methods. A national study in Mexico was conducted in 2009. Three possible methods for estimating a unit's optimum size were analyzed: hemodialysis services production under monopolistic market, under a perfect competitive market and production maximization given capital constraints. Results. The third method was considered best based on the assumptions made in this paper; an optimal size unit should have 16 dialyzers (15 active and one back up dialyzer) and a purifier system able to supply all. It also requires one nephrologist, five nurses per shift, considering four shifts per day. Conclusion. Empirical evidence shows serious inefficiencies in the operation of units throughout the country. Most units fail to maximize production due to not fully utilizing equipment and personnel, particularly their water purifier potential which happens to be the most expensive asset for these units.
| Reference Key |
vila-palomares2010saludestimacin
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | ;Paula Ávila-Palomares;Malaquías López-Cervantes;Luis Durán-Arenas |