solid-phase extraction with diethyldithiocarbamate as chelating agent for preconcentration and trace determination of copper, iron and lead in fruit wine and distilled spirit by flame atomic absorption spectrometry
Clicks: 249
ID: 201352
2011
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
30.0
/100
249 views
35 readers
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #48 of 235 articles by views in Journal of pharmaceutical and biomedical analysis
Most read
Least read
Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 235 in total.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Some heavy metals that present in wine and distilled spirit as background contamination are generally found at trace level particularly less than detection limit of common analytical techniques including flame atomic absorption spectrometry (FAAS). Thus, preconcentration method of the trace metals was developed. The optimum conditions for diethyldithiocarbamate (DDTC) complexes of Cu, Fe and Pb were then investigated for the preconcentration step using C18 solid-phase extraction prior to measurement by FAAS. The preconcentration factor of 15-fold was obtained with the appropriate ratio of sample volume used (150 mL) to 10 mL final volume giving their method recoveries of Cu, Fe and Pb found in the ranges of 96.5-107, 102-116 and 91.7-107%, respectively. Precision determinations (n = 10) for 0.1 mg L-1 of Cu, Fe and Pb each in a model solution were 3.7, 4.2 and 7.1 %RSD respectively. The detection limits (3SD) of Cu, Fe and Pb were found to be 1.4, 3.3 and 5.7 μg L-1, respectively. The developed method was applied to ten samples of local fruit wines and five samples of distilled spirits, resulting in the ranges of 0.012-0.80 and 0.12-8.8 mg L-1 for Cu; 0.18-3.4 and 0.036-0.29 mg L-1 for Fe and 0.0070-0.053 and 0.014-0.026 mg L-1 for Pb, respectively. Therefore, the method is simple and inexpensive for routine analysis of the trace metals in these samples to overcome limit of detection of the instrument used.
| Reference Key |
chanthal2011e-journalsolid-phase
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | ;Saksit Chanthal;Nongnoot Suwamart;Chalerm Ruangviriyachai |
| Journal | Journal of pharmaceutical and biomedical analysis |
| Year | 2011 |
| DOI |
10.1155/2011/416194
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.