a systematic review and meta-analysis of radiotherapy planning studies comparing multi leaf collimator designs
Clicks: 335
ID: 200052
2018
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
71.1
/100
335 views
236 readers
Trending
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #1 of 2 articles by views in fiat justisia
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Background and purpose: Several studies have investigated multi leaf collimator (MLC) leaf design. We performed a systematic review and meta-analysis of those studies to compare the impact of MLC leaf width used for different radiotherapy techniques. Materials and methods: We decided to focus on 2.5, 3.0 and 5.0 mm leaf width MLCs as it appeared to be the most contentious area from literature. We adopted Cochrane and PRISMA guidelines and computed the association between MLC leaf width and conformity index (CI) across the selected studies as pooled mean difference (PMD) with 95% confidence interval. Results: A total of 43 papers were selected from the literature search, of which ten compare MLC leaf width of 2.5 mm or 3.0 mm (MLC2.5 mm) versus 5.0 mm (MLC5 mm) in terms of CI. There was a slight, but significant, difference between MLC2.5 mm and MLC5 mm in favor of the former (mean difference −0.036; 95% confidence interval: −0.068 to −0.005). A subgroup analysis was performed by comparing techniques (intensity modulated radiation therapy vs conformal). In the intensity modulated radiation therapy (IMRT) subgroup, the difference between MLC2.5 mm and MLC5 mm appeared to be negligible (mean difference: −0.006; 95% confidence interval: −0.013 to 0.001) and not significantly different from zero. In the subgroup of studies which used conformal techniques, there was a significant difference between MLC2.5 mm and MLC5 mm (mean difference: −0.054; 95% confidence interval: −0.096 to −0.012). Conclusions: Introduction of IMRT produced comparable target coverage (CI) between 2.5 or 5.0 mm leaf width MLCs. Keywords: Multi leaf collimators, Treatment planning system, Intensity modulated radiation therapy, Systematic review, Meta-analysis
| Reference Key |
luzzara2018physicsa
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | ;Marco Luzzara;Luigi Santoro;Kevin Brown |
| Journal | fiat justisia |
| Year | 2018 |
| DOI |
DOI not found
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.