analysis of optical proprieties of the water reservoir rodolfo costa e silva – itaara, rs, brazil, with field spectral data and orbital multispectral images

Clicks: 111
ID: 199441
2007
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Steady

Ranked #37 of 47 articles by views in proceedings of 2017 3rd ieee international conference on sensing, signal processing and security, icsss 2017

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
An evaluation of the discrimination of water classes using continuum removal technique applied over spectral data obtained in field and multispectral images classification is presented. The study area was the Rodolfo Costa e Silva water reservoir, located in central region of Rio Grande do Sul (RS) State, in Southern region of Brazil. The methodology was based on in situ data collection of: total suspended solids, chlorophyll (a, b and c), water transparency, and bidirectional spectral reflectance. These data were collected in 21 point (samples) in May 16, 2006. The continuum removal technique was applied on the spectral data over 4 absorption bands: 400-550nm, 610-640nm, 650-680nm e 580-700nm. The continuum removal parameters analyzed for each absorption band were: depth, area and width. The multispectral images used were CBERS-2/CCD and Landsat 5/TM. The images were acquired in a date nearest to field work and with appropriate weather conditions. These images were corrected by removing atmospheric effects and then classified. According to the results obtained from the continuum removal technique, it was verified that band depth, area and width did not present a good potential to separate different water classes. Digital classification results did not show significant correlations with the limnological parameters collected in field and, therefore, could not be used to characterize spectrally different water classes or compartments. The main problem of establishing relationships between spectral reflectance and water quality parameters was due to the low variability of optical components in the water of Rodolfo Costa e Silva Reservoir. In this case the spectral analyses (considering both techniques) were not sensitive to the relative small variations observed in field data.
Reference Key
filho2007revistaanalysis Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors ;Waterloo Pereira Filho;Flávio Wachholz;Fábio Marcelo Breunig;Conrado de Moraes Rudorff
Journal proceedings of 2017 3rd ieee international conference on sensing, signal processing and security, icsss 2017
Year 2007
DOI
10.4136/ambi-agua.28
URL
Keywords Keywords not found

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.