ultra-high-performance liquid chromatography for the determination of exenatide in monkey plasma by tandem quadrupole mass spectrometry

Clicks: 194
ID: 196350
2013
Free PDF
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Popular

Ranked #152 of 187 articles by views in Frontiers in plant science

Most read Least read

Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 187 in total.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
A highly sensitive ultra-high-performance liquid chromatographic–tandem mass spectrometry (UPLC/MS/MS) method was developed for the quantification of the synthetic peptide drug of exenatide in monkey plasma. Sample preparation was carried out by solid-phase extraction (SPE), and bivalirudin was used as the internal standard (IS). An excellent chromatographic separation was obtained on a reversed-phase C18 column with a gradient elution. Detection utilized a Qtrap 5500 system operated in the positive ion mode with multiple reaction monitoring (MRM). The proposed method was validated by assessing the specificity, linearity, intra- and inter-day precision and accuracy, recovery, and stability. The method resulted in a linear calibration range of 0.10–30ng/mL, extracting with only 50μL monkey plasma aliquots. The intra- and inter-day precisions (as relative standard deviation) were less than 7.5% and 9.6%, respectively. The method could be successfully utilized for the pharmacokinetic study of exenatide in monkeys following a single subcutaneous injection of Byetta. Keywords: Exenatide, UPLC/MS/MS, Quantitation, Pharmacokinetics, Plasma, Monkey
Reference Key
zhang2013journalultra-high-performance Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors
Journal Frontiers in plant science
Year 2013
DOI
DOI not found
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.