broadband circular interferometric millimetre-wave isar for threat detection
Clicks: 82
ID: 195033
2007
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
24.3
/100
82 views
11 readers
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #39 of 52 articles by views in neuropsychiatrie : klinik, diagnostik, therapie und rehabilitation : organ der gesellschaft osterreichischer nervenarzte und psychiater
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
To detect threats on a person's body surface the application of millimetre-waves is possible. In order to get a view of the person from all sides either the person has to be rotated standing on a turntable (Inverse Synthetic Aperture Radar, ISAR) or a sensor is moved on a circular path around the person (Synthetic Aperture Radar, SAR). The goal of the reconstruction is to obtain information about the shape of the threats and their positions in all three dimensions. At first the reconstruction is done along range and azimuth, which span the principal surface given by the sensor configuration. This paper reports on two methods to obtain the third spatial dimension. Due to the circular shape and its 3D focussing ability of the aperture this information can be obtained by the evaluation of the image focus. Secondly, if two coherent receiving channels are used, a possibility to achieve 3D spatial resolution is the processing of the interferometric phase. A comparison between these two will be presented.
| Reference Key |
bertl2007advancesbroadband
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | ;S. Bertl;A. Dallinger;J. Detlefsen |
| Journal | neuropsychiatrie : klinik, diagnostik, therapie und rehabilitation : organ der gesellschaft osterreichischer nervenarzte und psychiater |
| Year | 2007 |
| DOI |
DOI not found
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.