biodegradable ptlga terpolymers versus collagen implants used as an adjuvant in trabeculectomy in rabbit eye
Clicks: 124
ID: 194923
2015
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
30.0
/100
124 views
16 readers
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #137 of 167 articles by views in chemical reviews
Most read
Least read
Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 167 in total.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Purpose. To evaluate the effectiveness and safety of three biodegradable terpolymers prepared from L-lactide, trimethylene carbonate, and glycolide (PTLGA) as an aid for trabeculectomy compared with the Ologen (OLO). Methods. Trabeculectomy was carried out on rabbits with implantation made from OLO or three PTLGA terpolymers. Intraocular pressure (IOP) was recorded 1, 2, 3, and 6 months postoperatively and bleb evaluations were performed using ultrasound biomicroscopy (UBM) 3 months after surgery, optical coherence tomography (OCT) every month, and transmission electron microscopy (TEM) six months after surgery followed by histological examination 1, 2, 3, and 6 months postoperatively. Result. IOP was significantly reduced in all groups after surgery. There were no significant differences in the IOL between groups at any time after implantation. There was no significant difference between the groups examined by OCT, UBM, and TEM. Exposure of the implant was observed in one eye from the OLO group and one eye in the P1. Subconjunctiva hyperblastosis was observed in one eye from group P3 and two eyes from the OLO group. Conclusions. Subconjunctival implantation of filtering devices made from PTLGA may present a safe and effective additional surgical tool for the treatment of filtering surgery. Fewer complications were observed in the group with P2 implants compared to other groups.
| Reference Key |
niu2015journalbiodegradable
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | ;Weiran Niu;Guanglin Shen;Yuanzhi Yuan;Xiaoping Ma;Suming Li;Jingzhao Wang;Zhongyong Fan;Lan Liao |
| Journal | chemical reviews |
| Year | 2015 |
| DOI |
10.1155/2015/737198
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.