effects of hydrologic conditions on swat model performance and parameter sensitivity for a small, mixed land use catchment in new zealand

Clicks: 128
ID: 194718
2015
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Steady

Ranked #219 of 303 articles by views in materials research bulletin

Most read Least read

Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 303 in total.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
The Soil Water Assessment Tool (SWAT) was configured for the Puarenga Stream catchment (77 km2), Rotorua, New Zealand. The catchment land use is mostly plantation forest, some of which is spray-irrigated with treated wastewater. A Sequential Uncertainty Fitting (SUFI-2) procedure was used to auto-calibrate unknown parameter values in the SWAT model. Model validation was performed using two data sets: (1) monthly instantaneous measurements of suspended sediment (SS), total phosphorus (TP) and total nitrogen (TN) concentrations; and (2) high-frequency (1–2 h) data measured during rainfall events. Monthly instantaneous TP and TN concentrations were generally not reproduced well (24 % bias for TP, 27 % bias for TN, and R2 < 0.1, NSE < 0 for both TP and TN), in contrast to SS concentrations (< 1 % bias; R2 and NSE both > 0.75) during model validation. Comparison of simulated daily mean SS, TP and TN concentrations with daily mean discharge-weighted high-frequency measurements during storm events indicated that model predictions during the high rainfall period considerably underestimated concentrations of SS (44 % bias) and TP (70 % bias), while TN concentrations were comparable (< 1 % bias; R2 and NSE both ~ 0.5). This comparison highlighted the potential for model error associated with quick flow fluxes in flashy lower-order streams to be underestimated compared with low-frequency (e.g. monthly) measurements derived predominantly from base flow measurements. To address this, we recommend that high-frequency, event-based monitoring data are used to support calibration and validation. Simulated discharge, SS, TP and TN loads were partitioned into two components (base flow and quick flow) based on hydrograph separation. A manual procedure (one-at-a-time sensitivity analysis) was used to quantify parameter sensitivity for the two hydrologically separated regimes. Several SWAT parameters were found to have different sensitivities between base flow and quick flow. Parameters relating to main channel processes were more sensitive for the base flow estimates, while those relating to overland processes were more sensitive for the quick flow estimates. This study has important implications for identifying uncertainties in parameter sensitivity and performance of hydrological models applied to catchments with large fluctuations in stream flow and in cases where models are used to examine scenarios that involve substantial changes to the existing flow regime.
Reference Key
me2015hydrologyeffects Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors ;W. Me;J. M. Abell;D. P. Hamilton
Journal materials research bulletin
Year 2015
DOI
10.5194/hess-19-4127-2015
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.