Glycemic control among diabetic patients in Ethiopia: A systematic review and meta-analysis.
Clicks: 345
ID: 19451
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
75.6
/100
345 views
281 readers
Trending
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #488 of 2,056 articles by views in PloS one
Most read
Least read
Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 2,056 in total.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Ethiopia recorded the highest numbers of people with diabetes in Africa. It is not uncommon for diabetic patients to have poor glycemic control leading to a number of complications. The aim of this systematic review and meta-analysis is to evaluate the level of glycemic control among diabetic patients in Ethiopia by combining the studies from the existing literature.The Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines was employed to plan and conduct this review. A comprehensive electronic-based literature search was conducted in the databases of MEDLINE, HINARI, GOOGLE SCHOLAR, and SCIENCEDIRECT. Open meta-analyst software was used to perform meta-analyses. Proportions of good glycemic control among diabetic patients was calculated. Odds ratio was also calculated to check the presence of statistically significant difference in glycemic control among patients with type 1 and type 2 diabetes.A total of 22 studies were included in the final analysis. Meta-analysis of 16 studies showed that only one-third of patients [34.4% (95% CI: 27.9%-40.9%), p<0.001] achieving good glycemic control based on fasting plasma glucose measurements. Similar to the studies that used fasting plasma glucose, the rate of good glycemic control was found to be 33.2% [(95% CI: 21.8%-44.6%), p<0.001] based on glycosylated hemoglobin measurements. There was no statistically significant difference in the rates of glycemic control between patients with type 1 and type 2 diabetes (p = 0.167).High proportion of diabetic patients were unable to achieve good glycemic control. There was no difference in glycemic control among type 1 and type 2 diabetic patients.
| Reference Key |
gebreyohannes2019glycemicplos
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Gebreyohannes, Eyob Alemayehu;Netere, Adeladlew Kassie;Belachew, Sewunet Admasu; |
| Journal | PloS one |
| Year | 2019 |
| DOI |
10.1371/journal.pone.0221790
|
| URL | |
| Keywords | Keywords not found |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.