stress-free bonding technology with pyrex for highly integrated 3d fluidic microsystems
Clicks: 90
ID: 194476
2014
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Popular Article
26.7
/100
90 views
4 readers
AI Quality Assessment
Not analyzed
Readership in this journal
PopularRanked #104 of 115 articles by views in chemistryopen
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
In this article, a novel Pyrex reflow bonding technology is introduced which bonds two functional units made of silicon via a Pyrex reflow bonding process. The practical application demonstrated here is a precision dosing system that uses a mechanically actuated membrane micropump which includes passive membranes for fluid metering. To enable proper functioning after full integration, a technique for device assembly must be established which does not introduce additional stress into the system, but fulfills all other requirements, like pressure tolerance and chemical stability. This is achieved with a stress-free thermal bonding principle to bond Pyrex to silicon in a five-layer stack: after alignment, the silicon-Pyrex-silicon stack is heated to 730 °C. Above the glass transition temperature of 525 °C Pyrex exhibits viscoelastic behavior. This allows the glass layer to come into close mechanical contact with the upper and lower silicon layers. The high temperature and the close contact promotes the formation of a stable and reliable Si-O-Si bond, without introducing mechanical stress into the system, and without deformation upon cooling due to thermal mismatch.
| Reference Key |
thoma2014micromachinesstress-free
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | ;Florian Thoma;Frank Goldschmidtböing;Keith Cobry;Peter Woias |