A carbon paste electrode modified with poly(methylene disulfide) nanoparticles for anodic stripping voltammetric determination of silver(I).

Clicks: 295
ID: 194
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Popular

Ranked #42 of 75 articles by views in Mikrochimica acta

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Poly(methylene disulfide) nanoparticles (PMDSNPs) were synthesized and characterized by FTIR, FESEM, EDX, and TGA. The nanomaterial was used to modify a carbon paste electrode to obtain a sensor for differential pulse anodic stripping voltammetric analysis of silver ion. The silver ions are accumulated on the modified electrode by reduction at a potential of -0.3 V. This is followed by the quantitation of adsorbed Ag(I) by differential pulse anodic stripping voltammetry. Under optimized conditions, the electrode has a dynamic range in the 3.0 × 10 to 1.0 × 10 mol L Ag(I) concentration range, and the detection limit is 1.0 × 10 mol L. The relative standard deviation (for n = 6) is 1.8%, this showing good reproducibility. The method was successfully applied to the determination of Ag(I) in spiked tap and river waters and tea leaves. The results were in good agreement with those obtained by inductively coupled plasma optical emission spectrometry. Graphical abstract Graphical presentation of synthesis of poly(methylene disulfide) nanoparticles (PMDSNPs) and their use as a modifier in a carbon paste electrode (MCPE). Differential pulse anodic stripping voltammograms of the MCPE for silver ion are compared with those of the bare CPE.
Reference Key
ghalebi2019a Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors Ghalebi, Seyedeh Mina;Zare-Shahabadi, Vahid;Parham, Hooshang;
Journal Mikrochimica acta
Year 2019
DOI
10.1007/s00604-018-3156-0
URL
Keywords Keywords not found

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.