simulations of the stopping efficiencies of fission ion guides
Clicks: 61
ID: 193860
2017
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Emerging Content
18.0
/100
61 views
9 readers
AI Quality Assessment
Not analyzed
Readership in this journal
EmergingRanked #508 of 625 articles by views in utilitas mathematica
Most read
Least read
Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 625 in total.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
With the Ion Guide Isotope Separator On-Line (IGISOL) facility, located at the University of Jyväskylä, products of nuclear reactions are separated by mass. The high resolving power of the JYFLTRAP Penning trap, with full separation of individual nuclides, capacitates the study of nuclides far from the line of stability. For the production of neutron-rich medium-heavy nuclides, fissioning of actinides is a feasible reaction. This can be achieved with protons from an in-house accelerator or, alternatively, with neutrons through the addition of a newly developed Be(p,xn)-converter. The hereby-obtained fission products are used in nuclear data measurements, for example fission yields, nuclear masses, Q-values and decay spectroscopy. Prior to separation, the ionized reaction products are stopped in a helium-filled gas cell, referred to as the ion-guide. In this work we present simulations of the stopping of fission products in an ion guide developed for neutron-induced fission. The production and extraction rates are evaluated and compared against experimental values.
| Reference Key |
andreas2017epjsimulations
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | ;Solders Andreas;Al-Adili Ali;Gorelov Dmitry;Jansson Kaj;Jokinen Ari;Kolhinen Veli;Lantz Mattias;Mattera Andrea;Moore Ian;Nilsson Niklas;Norlin Martin;Penttilä Heikki;Pomp Stephan;Prokofiev Alexander V.;Rakopoulos Vasileios;Rinta-Antila Sami;Simutkin Vasily |
| Journal | utilitas mathematica |
| Year | 2017 |
| DOI |
10.1051/epjconf/201714603025
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.