assessing wear and surface roughness of different composite resins after toothbrushing
Clicks: 340
ID: 193291
2001
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Popular Article
30.0
/100
340 views
73 readers
AI Quality Assessment
Not analyzed
Readership in this journal
PopularRanked #12 of 96 articles by views in Majalah Ilmiah Teknologi Elektro
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
The aim of this work was to compare the in vitro wear and roughness of different composite resins after toothbrushing. Six resins were tested: Revolution (Kerr), Natural Flow (DFL), Flow It! (Jeneric-Pentron), Fill Magic Flow (Vigodent) - flowable composites, Silux Plus (3M) - microfilled composite, and Z100 (3M) - hybrid composite. Eight disks were prepared for each group (n = 48), with 12 mm in diameter and 1mm thick. The specimens were stored in distilled water at 37 °C for 7 days, polished (Super Snap), weighed and submitted to the initial roughness test. Each sample was fixed on plexiglass plates and subjected to simulated toothbrushing. After abrasion, the samples were removed from the plates, weighed and submitted to the post-abrasion roughness test. Statistical analysis was performed by using ANOVA and Tukey's test. Pearson's test was used to verify correlation between wear and roughness. Data showed a similar resistance to wear of Natural Flow and Z100, both presenting minimum mass loss and surface roughness. Silux Plus presented the roughest surface after toothbrushing.
| Reference Key |
chimello2001materialsassessing
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | ;D.T. Chimello;R.G.P. Dibb;S.A.M. Corona;E.H.G. Lara |
| Journal | Majalah Ilmiah Teknologi Elektro |
| Year | 2001 |
| DOI |
10.1590/S1516-14392001000400011
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.