comparison of two analytical platforms for csf biomarkers of alzheimer’s disease

Clicks: 147
ID: 192611
2014
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Steady

Ranked #885 of 1,324 articles by views in spectrochimica acta - part a: molecular and biomolecular spectroscopy

Most read Least read

Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 1,324 in total.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Cerebrospinal fluid (CSF) biomarkers of Alzheimer’s disease (AD) are currently being assessed with two different assays. Our objective was to study if there is a correlation between values obtained by both techniques, to compare their validity and search for conversion factor between values obtained for every protein. We compared the performances of two commonly used platforms, an enzyme-linked immunosorbent assay (ELISA) and a multiplex (xMAP) technology for measurement of CSF Aβ1–42, total tau (T-tau), and phosphorylated tau 181 (P-tau181p) proteins, in 30 AD patients and 28 control subjects. The relations between the variables of both techniques were evaluated using the Spearman p correlation coefficient (α=0.05). Receiver operating characteristic and area under the curve (AUC) analyses were calculated for the variables of both techniques. The two assays platforms yielded different absolute values for the various analytes, always higher in ELISA. We found some correction factor between values: 2,1- to 3-fold for Aβ1–42; 4,1- to 4,6-fold for T-tau; and 1,4- to 1,6-fold for P-tau181p. In addition, those values were highly correlated (Aβ1–42: r=0.70, P<0.01; T-tau: r=0.90, P<0.01; P-tau181p: r=0.85, P<0.01) and the AUC for the variables showed very similar values. In conclusion, the results obtained with ELISA and xMAP platforms were highly correlated and its validity is very similar. Differences in absolute values point to the need for a clear description of the technique used. Moreover, we found some conversion factor between values of every protein that may be useful for transformation between both techniques.
Reference Key
monge-argils2014biomedcomparison Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors ;Jose Antonio Monge-Argilés;Carlos Muñoz-Ruiz;José Sánchez-Payá;Ruth Gasparini Berenguer;Maria Empar Blanco Cantó;Carlos Leiva-Santana
Journal spectrochimica acta - part a: molecular and biomolecular spectroscopy
Year 2014
DOI
10.1155/2014/765130