Technoeconomic modelling and environmental assessment of a modern PEMFC CHP system: a case study of an eco-house at University of Nottingham.

Clicks: 297
ID: 19162
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Steady

Ranked #214 of 403 articles by views in Environmental science and pollution research international

Most read Least read

Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 403 in total.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
This simulation study is aimed to model a contemporary Proton Exchange Membrane fuel cell (PEMFC) CHP system having a 'heat and power' autonomy as well as a provision of demand-driven electrical supply to the grid. A novel nanowire-electrode PEMFC stack is adopted within this PEMFC CHP system so to effectively replace the existing natural gas fuelled durable solid oxide fuel cell (SOFC) CHP system installed at David Wilson Millennium Eco-house at University of Nottingham. The energy savings, environmental, and economic performances of the proposed PEMFC system are determined and compared to the base case (SOFC) which is operated continuously to maintain a 1.5 kWe. While to meetup the highly fluctuating and seasonal demands of heating and power like in the UK, a PEMFC is more productive and advantageous over a SOFC. The proposed PEMFC unlike to the SOFC will be able to operate and adjust its output and turn down instantly as per changing conditions of ambient temperatures and loads in terms of electricity and heat. The results of the modelling predicted that as compared to the base case scenario, this PEMFC CHP system will efficiently reduce an annual CO emission by 65.99% and fiscal costs by 66.74% with a viable internal rate of return as 8.93% and benefit to cost ratio as 1.02.
Reference Key
sui2019technoeconomicenvironmental Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors Sui, Sheng;Rasheed, Rizwan;Li, Qinglin;Su, Yuehong;Riffat, Saffa;
Journal Environmental science and pollution research international
Year 2019
DOI
10.1007/s11356-019-06054-5
URL
Keywords Keywords not found

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.