validated hplc method for the determination of nocodazole in solid lipid nanoparticle formulations
Clicks: 257
ID: 190876
2014
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
30.0
/100
257 views
70 readers
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #12 of 20 articles by views in petroleum exploration and development
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Nocodazole (NCD) is an anti-neoplastic agent which exerts its effect in cells by interfering with the polymerization of microtubules. As NCD affects the cytoskclcton. it is often used inceli biology experiments as a control. In tlıis study, NCD was loaded into Solid Lipid Nanoparticle (SLN) Systems. A reverse plıase lıigh perfonnance liquid clıromatography (HPLC) method was validated and applied forthe detennination of NCD in SLN. Determination and validation studies were carried out on a 4.6 % 150 inin, 5pırı Cı8 Thenno column using an optimized mobile plıase (MP) of methanol:water:phosplıate buffer (45:42.5:12.5, v/v/v , pH 5.03) at a flow rate of 0.8 ınL/min. Diode array detection was perfonned at 256 mn and the column temperature was adjusted to 40°C. Naproxen was used as an intemal Standard (IS). The retention times for naproxen and NCD were 2.2 and 9.8 inin, respectively. The specifıed working range was derived from linearity studies and kept in the concentration range 0.5-100 ppm. Limit of dedection (LOD) and limit of quantitation (LOQ) values were detennined to be 0.065 ppm and 0.196 ppm, respectively. NCD recovery % results of the SLN fonnulations which are stored at 25°C, 4°C and 40°C were investigated and compared to the freslıly prepared samples
| Reference Key |
dkmen2014turkishvalidated
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | ;Gökhan DİKMEN;Lütfi GENÇ;Erol ŞENER |
| Journal | petroleum exploration and development |
| Year | 2014 |
| DOI |
DOI not found
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.