simulation of electromagnetic influence of railway overhead contact system on disconnected transmission lines by the atp-emtp programme

Clicks: 151
ID: 190728
2016
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Emerging

Ranked #27 of 32 articles by views in journal of youth and adolescence

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
This paper is devoted to experimental and calculating research of induced voltage on disconnected transmission lines caused by the influence of AC railway overhead contact system. Theoretical researches have been carried out by means of mathematical modeling in the ATP-EMTP programme. The programme allows simulate the power lines and traction networks using their physical parameters taking into account changes of the mutual arrangement of geometry. The values of currents and voltage of a traction network have been used as input data for the researches. Experimental research of induced voltages and currents in the traction network has been performed on the overhead transmission line and single-track railway section located near. For the design study of the induced voltage the models of convergence of the objects in two versions have been constructed: when there are one and two rolling trains on the influencing railway section. In most cases comparing results of calculating and experimental researches of the induced voltage on the line examined has shown little relative accuracy of the calculated values (4–7 %). The research results allow us recommend the programme complex ATP-EMTP use to assess of induced voltage level on the disconnected overhead power lines having convergence sections with electrified railways with the possibility to use maximum dynamic current of inducted contact network.
Reference Key
2016vestniksimulation Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors ;Zalesova O. V.
Journal journal of youth and adolescence
Year 2016
DOI
10.21443/1560-9278-2016-4-715-722
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.