noninvasive assessment of patency of internal ureteral stent: role of colour doppler ultrasound

Clicks: 196
ID: 190354
2004
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Popular

Ranked #146 of 248 articles by views in journal of molecular structure

Most read Least read

Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 248 in total.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
To compare colour Doppler ultrasonography (CDU) and retrograde cystography in the assessment of the patency of internal ureteral stents. Patients and Methods: Thirty-two patients with 33 internal ureteral stents were evaluated for patency of the internal ureteral stent using both CDU and retrograde cystography. Real-time ultrasonography and CDU were performed before retrograde cystography. Stent patency was defined as seeing flow from the distal end of the stent in the urinary bladder or iodinated contrast in the renal pelvis. The two investigators had no prior knowledge of the other's results. After completion of both investigations, stent patency was proved by direct inspection of the stent after removal. Results: Both investigations showed the same result in 27 of the 33 stents. Stent patency was found if either investigation was positive. The accuracies of retrograde cystography, CDU and both were 73%, 79% and 85%, respectively. Conclusions: CDU is a noninvasive method with high accuracy. Detection of flow at the distal end of the stent is helpful, but absence of flow may or may not indicate an obstructed stent and further investigation should be performed.
Reference Key
lojanapiwat2004asiannoninvasive Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors ;Bannakij Lojanapiwat
Journal journal of molecular structure
Year 2004
DOI
10.1016/S1015-9584(09)60059-2
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.