establishing the influence of the in-house water distribution system and sampling procedures on the microbiological quality of drinking water

Clicks: 198
ID: 190293
2005
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Steady

Ranked #109 of 231 articles by views in planta medica

Most read Least read

Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 231 in total.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract

Background: The purpose of this study was to find out how the in-house water distribution system affects the microbiological quality of drinking water and to find a suitable way to evaluate the results of microbiological tests according to the sampling locations, develop methods for establishing the influence of the in-house water distribution system on the quality of drinking water and evaluate the suitability of some procedures for sampling.

Methods: The study was conducted in south-eastern Slovenia between October 2003 and October 2004, thereby eliminating the influence of the seasons. Four-hundred-and-sixty-eight samples of drinking water were included in the study.

Results: The results of the samples included in this study suggest (p < 0.05) that the first flush samples do not contain Escherichia coli more often than the samples after flushing and the sample from the primary water distribution system. The results also show that the heterotrophic plate count is significantly higher in the first flush samples (p < 0.001).

Conclusions: The study demonstrated that the in-house water distribution system affects the microbiological quality of drinking water, and that certain sampling methods significantly affect the test results, and also that knowing the characteristics of the sampling locations is also of significant importance. Some results cannot be analyzed well, therefore additional research is needed.

Reference Key
harlander2005zdravnikiestablishing Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors ;Dušan Harlander;Matjaž Retelj;Bonia Miljavac