an investigation of influencing factors on practical sub-diffraction-limit focusing of planar super-oscillation lenses
Clicks: 181
ID: 190156
2018
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Emerging Content
30.0
/100
181 views
22 readers
AI Quality Assessment
Not analyzed
Readership in this journal
EmergingRanked #116 of 133 articles by views in progress in neuro-psychopharmacology & biological psychiatry
Most read
Least read
Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 133 in total.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Planar super-oscillation lenses (SOLs) can fulfill super-resolution focusing and nanoscopic imaging in the far field without the contribution of evanescent waves. Nevertheless, the existing deviations between the design and experimental results have been seldomly investigated, leaving the practical applications of SOLs unpredictable and uncontrollable. In this paper, some application-oriented issues are taken into consideration, such as the inevitable fabrication errors and the size effect of the designed SOLs, with the aim of providing an engineering reference to elaborately customize the demanded focusing light field. It turned out that a thicker structural film makes the focal spots enlarged, while the sloped sidewalls just weaken the intensity of the focal hotspot. Furthermore, the focal lengths are diminished with the decrease of device size, while the focal spots are enlarged. This research will promote the wide-spread applications of SOLs for sub-diffraction-limit far-field focusing in the areas of nanoscopy and high-density optical storage.
| Reference Key |
yu2018nanomaterialsan
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | ;Yiting Yu;Wenli Li;Haoyong Li;Muyuan Li;Weizheng Yuan |
| Journal | progress in neuro-psychopharmacology & biological psychiatry |
| Year | 2018 |
| DOI |
10.3390/nano8040185
|
| URL | |
| Keywords | Keywords not found |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.