multiparameter microwave characterization and probing of ultralow glucose concentration using a microfabricated biochip
Clicks: 90
ID: 189672
2016
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
26.7
/100
90 views
18 readers
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #106 of 115 articles by views in chemistryopen
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
This paper presents a planar biochip consisting of electromagnetically coupled, symmetric, square open loops for the multiparameter microwave characterization of deionized water, a phosphate-buffered saline solution, and a fructose-deionized water solution. The characterization additionally includes the probing of an ultralow glucose concentration in a very small volume of human sera and in solutions of d-glucose powder and deionized water. The interaction between the coupled electromagnetic field and the aqueous solution sample translates into a predictable relationship between the electrical characteristics of the biochip (magnitude and phase of S-parameters, attenuation, phase constant, group delay, characteristic impedance, and effective complex permittivity) and the physical properties of the solution. Owing to the microfabrication technology used for fabricating the proposed microbiochip, it is possible to develop robust, compact square open loops with a microsized coupling gap that characterizes a very small volume (1 μL) of the sample. Additionally, the biochip’s impedance peaks at its resonances were modeled using glucose-level-dependent coupling capacitance between folded square open loops and mutual inductance between center-loaded T-shaped stubs. These peaks linearly shifted in frequencies and markedly varied in impedance. Consequently, a physiologically relevant amount of glucose (50–400 mg/dL) with a high sensitivity (up to 2.036 Ω/(mg·dL−1)) and an ultralow detection limit (up to 4.8 nmol/L) was linearly detected.
| Reference Key |
adhikari2016micromachinesmultiparameter
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | ;Kishor Kumar Adhikari;Eun Seong Kim;Nam Young Kim |
| Journal | chemistryopen |
| Year | 2016 |
| DOI |
10.3390/mi7060093
|
| URL | |
| Keywords | Keywords not found |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.