Ultrasound assisted combined molecularly imprinted polymer for the selective micro-solid phase extraction and determination of aflatoxins in fish feed using liquid chromatography-tandem mass spectrometry.
Clicks: 284
ID: 18955
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
62.8
/100
284 views
230 readers
Trending
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #34 of 58 articles by views in journal of chromatography a
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
A combined procedure based on using ultrasounds for target isolation followed by porous membrane-protected micro solid phase extraction using a molecularly imprinted polymer as an adsorbent has been developed as a highly selective extraction and clean-up procedure for isolating aflatoxins B1, B2, G1, and G2 from fish feed before ultra-high-performance liquid chromatography tandem mass spectrometry determination. Polymeric adsorbent beads have been synthesized by the precipitation polymerization method which guarantees a homogeneous particles size distribution and the integrity of the generated imprinted cavities. In addition, polymerization was performed using a higher proportion of organic solvent (toluene) in the porogen mixture, which generates MIP particles adequate for interacting with targets dissolved in organic (hydro-organic) mixtures (extracts from fish feed). These approaches led to a selective and high efficient pre-concentration method for AFs. Ultrasound-assisted extraction (10 mL of 60:40 acetonitrile/0.1 M KHPO pH 6.0, 40% amplitude, continuous sonication for 7.0 min) allowed an efficient aflatoxins isolation from fish feed. In addition, the resulting pH of the extract (pH 7.0) has been found to be the optimum for performing clean-up/pre-concentration (enrichment factor of 33.3) by molecularly imprinted polymer based micro-solid phase extraction (orbital horizontal shaking speed at 150 rpm for 10 min for loading, and 5 mL of 95:5 acetonitrile/formic acid as eluting solution using ultrasounds 35 kHz for 15 min). The current proposal was shown to be an accurate and precise method through relative standard deviation of intraday and inter-day tests below 20% and analytical recoveries in the range of 80-100%. The limits of detection were within the 0.42-1.15 μg kg range, quite lower than those established by European Commission guidelines for aflatoxins in animal feeds.
| Reference Key |
jayasinghe2019ultrasoundjournal
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Jayasinghe, G D Thilini Madurangika;Domínguez-González, Raquel;Bermejo-Barrera, Pilar;Moreda-Piñeiro, Antonio; |
| Journal | journal of chromatography a |
| Year | 2019 |
| DOI |
S0021-9673(19)30816-7
|
| URL | |
| Keywords | Keywords not found |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.