Single-Particle LRET Aptasensor for the Sensitive Detection of Aflatoxin B1 with Upconversion Nanoparticles.
Clicks: 298
ID: 18953
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Emerging Content
79.3
/100
298 views
245 readers
Trending
AI Quality Assessment
Not analyzed
Readership in this journal
EmergingRanked #40 of 194 articles by views in Analytical chemistry
Most read
Least read
Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 194 in total.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Contamination of foods and feeds by aflatoxins is a universal yet serious problem all over the world. Particularly, aflatoxin B1 (AFB1) is the most primary form and readily leads to terrible damages to human health. In this work, we construct a sensitive aptasensor based on single-particle detection (SPD) to analyze AFB1 in peanut samples with luminescence resonance energy transfer (LRET) between the aptamer modified upconversion nanoparticles (UCNPs-aptamer) and gold nanoparticles (GNPs). The UCNP-aptamer plays as the luminescence donor, while GNP acts as the energy acceptor. In the absence of AFB1, GNPs would adsorb onto the surface of UCNPs-aptamer because of the association between aptamers and GNPs, leading to luminescence quenching. However, the luminescence of UCNPs-aptamer is recovered gradually in the presence of AFB1 because the aptamers possess stronger affinity toward AFB1 than GNPs. Through statistically counting the number of luminescent particles on the glass slide surface, the concentration of AFB1 in solution is accurately determined. The linear dynamic range for AFB1 detection is from 3.13 to 125.00 ng/mL. The limit-of-detection (LOD) is 0.17 ng/mL, which is much lower than the allowable concentration in foods. As a result, this method would provide promising application for the sensitive detection of AFB1 in foods and feeds, which might make a meaningful contribution to food safety and public health in the future.
| Reference Key |
wang2019singleparticleanalytical
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Wang, Fuyan;Han, Yameng;Wang, Shumin;Ye, Zhongju;Wei, Lin;Xiao, Lehui; |
| Journal | Analytical chemistry |
| Year | 2019 |
| DOI |
10.1021/acs.analchem.9b02599
|
| URL | |
| Keywords | Keywords not found |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.