comparison and calibration of mobile phone fisheye lens and regular fisheye lens via equidistant model
Clicks: 134
ID: 188694
2016
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
30.0
/100
134 views
31 readers
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #150 of 205 articles by views in BMC infectious diseases
Most read
Least read
Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 205 in total.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Nowadays, mobile phones are more than a device that can only satisfy the communication need between people. In addition to providing ease to human lives with various applications, lens kits that can be integrated to mobile phones have recently been introduced. Fisheye lenses that are compliant with mobile phones are one of these new types of equipment. Since fisheye lenses integrated with mobile phones are lightweight and easy to use, they are advantageous. In addition to this advantage, whether fisheye lens and mobile phone combination can be used in a photogrammetric way is experimented, and if so, what will be the result. The main purpose of this study is to test fisheye lens equipment used with mobile phones. In this study, standard calibration of “Olloclip 3 in one” fisheye lens used with iPhone 4S mobile phone and “Nikon FC-E9” fisheye lens used with Nikon Coolpix8700 are compared based on equidistant model. The results of these calibrations are analyzed, using photogrammetric bundle block adjustment. This study suggests a precalibration process of these kinds of hardware for the photogrammetric process in the test field.
| Reference Key |
sahin2016journalcomparison
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | ;Cumhur Sahin |
| Journal | BMC infectious diseases |
| Year | 2016 |
| DOI |
10.1155/2016/9379203
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.