acrylic toric intraocular lens implantation: a single center experience concerning clinical outcomes and postoperative rotation

Clicks: 175
ID: 188643
2010
Free PDF
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Popular

Ranked #171 of 271 articles by views in e3s web of conferences

Most read Least read

Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 271 in total.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Ioannis T Tsinopoulos1, Konstantinos T Tsaousis1, Dimitrios Tsakpinis1, Nikolaos G Ziakas2, Stavros A Dimitrakos112nd Department of Ophthalmology, Aristotle University of Thessaloniki, Papageorgiou General Hospital, Thessaloniki, Greece; 21st Department of Ophthalmology, Aristotle University of Thessaloniki, AHEPA General Hospital, Thessaloniki, GreecePurpose: To present clinical results of toric intraocular lens (IOL) implantation for preexisting astigmatism correction and determine the time of any postoperative rotation.Patients and methods: Twenty-nine eyes of 19 patients underwent uncomplicated phacoemulsification and were implanted with an Acrysof© toric IOL. Uncorrected visual acuity, residual astigmatism, and postoperative rotation of the IOL were estimated one and six months after the operation.Results: Uncorrected visual acuity was ≥0.5 in 26 of 29 eyes (89.7%) and ≥0.8 in 19 of 29 patients (65.5%). The mean toric IOL axis rotation was 2.2 ± 1.5° (range 0.6–7.8°) one month postoperation and 2.7 ± 1.5° (range 0.9–8.4°) six months postoperation.Conclusion: Implantation of one-piece hydrophobic acrylic toric IOLs appears to have acceptable stability, which encourages visual outcome and emerges as an attractive alternative for correction of refractive astigmatism.Keywords: astigmatism, cataract, stability, implantation
Reference Key
tsinopoulos2010clinicalacrylic Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors
Journal e3s web of conferences
Year 2010
DOI
DOI not found
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.