Glutathione detection in human serum using gold nanoparticle decorated, monodisperse porous silica microspheres in the magnetic form.
Clicks: 337
ID: 188245
2020
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
30.0
/100
337 views
32 readers
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #3 of 5 articles by views in Analytical methods : advancing methods and applications
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
A nanozyme for glutathione (GSH) detection in a broad concentration range was synthesized. GSH is usually detected up to an upper limit of 100 μM using current noble metal nanozymes due to the sharp decrease in the colorimetric response with the increasing GSH concentration. Strong inhibition of colorimetric reactions by GSH adsorbed onto noble metal based nanozymes in the form of non-porous, nanoscale particulate materials dispersed in an aqueous medium is the reason for the sharp decrease in the colorimetric response. In the present study, a new magnetic nanozyme synthesized by immobilization of Au nanoparticles (Au NPs) on magnetic, monodisperse porous silica microspheres (>5 μm) obtained by a "staged-shape templating sol-gel protocol" exhibited peroxidase-like activity up to a GSH concentration of 5000 μM. A more controlled linear decrease in the peroxidase-like activity with a lower slope with respect to that of similar nanozymes was observed with the increasing GSH concentration. The proposed design allowed the GSH detection in a broader concentration range depending on the adsorption of GSH onto the Au NPs immobilized on magnetic, monodisperse porous silica microspheres. A calibration plot allowing the detection of GSH in a broad concentration range up to 3300 μM was obtained using the magnetic nanozyme. The GSH concentration was also determined in human serum by elevating the upper detection range and adjusting the sensitivity of detection via controlling the nanozyme concentration.
| Reference Key |
gokcal2020glutathioneanalytical
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Gökçal, Burcu;Hamaloğlu, Kadriye Özlem;Kip, Çiğdem;Güngör, Selen Yağmur;Büber, Esra;Tuncel, Ali; |
| Journal | Analytical methods : advancing methods and applications |
| Year | 2020 |
| DOI |
10.1039/d0ay01292k
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.