Identification of new process-related impurity in the key intermediate in the synthesis of TCV-116.
Clicks: 286
ID: 18797
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Emerging Content
66.1
/100
286 views
176 readers
Trending
AI Quality Assessment
Not analyzed
Readership in this journal
EmergingRanked #20 of 56 articles by views in acta pharmaceutica
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Development of safe and effective drugs requires complete impurity evaluation and, therefore, knowledge about the formation and elimination of impurities is necessary. During impurity profiling of a key intermediate during synthesis of candesartan cilexetil (1-(((cyclohexyloxy)carbonyl) oxy)ethyl 1-((2'-(2H-tetrazol-5-yl)-[1,1'-biphenyl]-4-yl) methyl)-2-ethoxy-1H-benzo[d]imidazole-7-carboxylate, TCV-116), a novel compound, which had not been reported previously, was observed. Structural elucidation of impurity was achieved by liquid chromatography hyphenated to different high resolution mass analyzers. Based on exact mass measurements and fragmentation pattern, a chloro alkyl carbonate ester analogue of the intermediate was identified. Structure of the impurity was confirmed by mass spectro-metric and NMR analyses of the target substance. Identified impurity could represent a hazard if it is transferred to the final API stage and its presence should be kept below allowed limits. Further investigation could reveal whether bis(1-chloroethyl) carbonate is a precursor to impurity formation. Therefore, synthesis should be regulated so as to minimize impurity production. Analysis of the final product indicated that the amount of impurity did not exceed 50 mg L-1, which represents the detection limit, determined according to the signal/noise ratio.
| Reference Key |
testen2019identificationacta
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Testen, Ana;Plevnik, Miha;Štefane, Bogdan;Cigić, Irena Kralj; |
| Journal | acta pharmaceutica |
| Year | 2019 |
| DOI |
10.2478/acph-2019-0006
|
| URL | |
| Keywords | Keywords not found |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org