breast milk iodine and iodine status of breast-fed infants

Clicks: 199
ID: 186729
2015
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Background: Breast milk is the only source of iodine for exclusively breast-fed infants. Iodine status of breast-fed infants depends on iodine in breast milk and also number of feeding in 24 hours. Iodine deficiency and iodine excess both have bad impact on infant’s health. Objective: To measure the iodine in breast milk and to evaluate iodine status of their breast-fed infants. Materials and method: This observational analytical study was carried out in the department of Biochemistry, Bangabandhu Sheikh Mujib Medical University, Dhaka with active cooperation of Kumudini Women’s Medical College Hospital, Mirzapur, Tangail involving fifty lactating mothers and their exclusively breast-fed infants. Early morning urine and breast milk samples were collected in dry and clean plastic container free from any chemical contamination. Urinary iodine was used as indicator for assessing iodine status. All statistical analyses were done by using SPSS (statistical programme for social science) 12 version software package for Windows. Results: The median (range) urinary iodine concentration of lactating mothers and their breast-fed infants were 225.25 μg/L (61.50-530.00) and 225.75 μg/L (100.50-526.00) respectively. The median (range) breast-milk iodine concentration was 157 μg/L (54.50-431.50) which was more than three times of recommended minimum concentration (50 μg/L). Only 2 (4%) lactating mothers had mild biochemical iodine deficiency (UIE, 50-99 μg/L). There was no biochemical iodine deficiency of breast-fed infants. Iodine in breast milk of lactating mothers was positively correlated with their urinary iodine excretion (p<0.01). Infant’s urinary iodine was positively correlated with iodine concentration in breast milk (p<0.01) and with urinary iodine of lactating mothers (p<0.01). Conclusion: Lactating mothers and their breast-fed infants in this study were iodine sufficient. If iodine content of breast-milk is within normal range, 10-12 numbers of feeding in 24 hours for infants is enough to get sufficient iodine from their mother’s milk.
Reference Key
molla2015deltabreast Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors ;Golam Morshed Molla;M Iqbal Arslan;Mafruha Tazkin Milky
Journal delta medical college journal
Year 2015
DOI
10.3329/dmcj.v3i2.24426
URL
Keywords Keywords not found

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.