ultrasound-assisted chiral derivatization of etodolac with (1r)-(−)-menthyl chloroformate for the determination of etodolac enanti

Clicks: 268
ID: 186220
2016
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Steady

Ranked #77 of 167 articles by views in Behavioural brain research

Most read Least read

Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 167 in total.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
This study presents the first report of an ultrasound-assisted derivatization reaction between a carboxylic acid of etodolac (ETO) and a chiral derivatization reagent, (1R)-(−)-menthyl chloroformate (R-MCF). Fifty μL of deproteinated mouse serum containing ETO enantiomers was derivatized with 125 μL of 200 mM R-MCF and 17 μL of pyridine (a catalyst), with the reaction facilitated by ultrasonic radiation for 13 min, which were the optimal conditions as determined by response surface methodology. After quenching the reaction by adding an aqueous L-proline solution, the mixture was subjected to salting-out assisted liquid–liquid extraction (SA-LLE), which provided phase separation for sample concentration as well as cleanup. The ETO diastereomers were separated on a Phenomenex Gemini C18 column (150 × 4.6 mm, 5 μm) under a simple gradient elution of a mobile phase containing a mixture of methanol: acetonitrile (10:1, V/V) and 10 mM acetic acid at a flow rate of 1.0 mL min−1, followed by fluorescence detection with excitation and fluorescence emission wavelengths of 235 nm and 345 nm, respectively. The developed method was validated for specificity, sensitivity, linearity, accuracy, precision, stability, and matrix effect. A good linearity in the range of 0.5–50.0 μg mL−1 for each ETO enantiomer with r2 > 0.998 and acceptable values for the intra-day and inter-day accuracy and precision as well as negligible matrix effects supported the suitability and reliability of the method. Finally, this method was used to analyze real samples taken from mice treated with (±)-ETO.
Reference Key
jin2016arabianultrasound-assisted Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors ;Yan Jin;Jing Zhao;Lydia Rhyman;Ponnadurai Ramasami;Yujin Shin;Kyung Min Jeong;Jeongmi Lee
Journal Behavioural brain research
Year 2016
DOI
10.1016/j.arabjc.2015.11.001
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.