detection of endoscopic looping during colonoscopy procedure by using embedded bending sensors

Clicks: 243
ID: 185329
2018
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Emerging

Ranked #4 of 12 articles by views in tms annual meeting

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Michael Bruce,1 JungHun Choi2 1Department of Mechanical Engineering, Ohio University, Athens, OH, USA; 2Department of Mechanical Engineering, Georgia Southern University, Statesboro, GA, USA Background: Looping of the colonoscope shaft during procedure is one of the most common obstacles encountered by colonoscopists. It occurs in 91% of cases with the N-sigmoid loop being the most common, occurring in 79% of cases. Purpose: Herein, a novel system is developed that will give a complete three-dimensional (3D) vector image of the shaft as it passes through the colon, to aid the colonoscopist in detecting loops before they form. Patients and methods: A series of connected links spans the middle 50% of the shaft, where loops are likely to form. Two potentiometers are attached at each joint to measure angular deflection in two directions to allow for 3D positioning. This 3D positioning is converted into a 3D vector image using computer software. MATLAB software has been used to display the image on a computer monitor. For the different configuration of the colon model, the system determined the looping status. Results: Different configurations (N loop, reverse gamma loop, and reverse splenic flexure) of the loops were well defined using 3D vector image. Conclusion: The novel sensory system can accurately define the various configuration of the colon during the colonoscopy procedure. Keywords: colonoscopy, endoscopy, loop, 3D vector image, intubation
Reference Key
m2018medicaldetection Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors ;Bruce M;Choi JH
Journal tms annual meeting
Year 2018
DOI
DOI not found
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.